Fire Ratings A. Jandris & Sons

Fire Ratings For Concrete Masonry Units Using Equivalent Thickness Method as permitted by the International Building Code (IBC) FIRE RATINGS HOURS UNIT WIDTH BLOCK TYPE FACE SHELL % SOLID EQUIVALENT THICKNESS NORMAL WEIGHT CONCRETE (Siliceous Gravel) MEDIUM WEIGHT (105-125lb per cubic ft blended) LIGHT WEIGHT (Under 105lbs per cubic ft) (Expanded

Get Price
[]

Report ESR 4043 Fastenal

3.2 Concrete Normal-weight and lightweight concrete must comply with Sections 1903 and 1905 of the IBC as applicable. 4.0 DESIGN AND INSTALLATION 4.1 Strength Design 4.1.1 General Design strength of anchors complying with the 2015 IBC, as well as Section R301.1.3 of the 2015 IRC must be determined in accordance with ACI 318-14

Get Price

Theut Products Inc. Concrete Company

Our company, Theut Products, Inc., has been producing lightweight and concrete block since 1937. With over 75 years of experience serving southeast Michigan, Theut is

Get Price

Lightweight Concrete Masonry

Lightweight concrete masonry units came into wide use in the U.S. in the 1950s. It's easy to see why the product gained rapidly in popularity. The average normal weight concrete masonry unit tips the scales at 34 pounds or more, medium weight units at between 28 and 34 pounds.

Get Price
[]

FIRE & SOUND IN MULTIFAMILY FLOORS

of concrete that is being poured . Despite being "lightweight," the overall load of the concrete on the assembly is greater than a plywood or gypsum underlayment solution . In addition, a lightweight concrete solution is typically double the height of a plywood or gypsum underlayment solution and negatively impacts floor-to-ceiling dimensions .

Get Price
[]

Number 449

3.2 Concrete Normal-weight and lightweight concrete shall conform to Sections 1901 and 1903 of the 2015 and 2012 IBC or Section 1903 and 1905 of the 2009 and 2006 IBC. The specified compressive strength of the concrete, f´, shall be from 2,500 psi to 8,500 psi (17.2 MPA to 58.6 MPa). 4.0 DESIGN AND INSTALLATION 4.1 Strength Design

Get Price
[]

ICC-ES Evaluation Report ESR-2713 SR Contractors, LLC

and uncracked normal-weight concrete and sand-lightweight concrete members having a specified compressive strength, ′c, from 2,500 psi to 8,500 psi f (17.2 MPa to 58.6 MPa); and cracked and uncracked sand-lightweight or normal-weight concrete over profile steel deck having a minimum specified compressive strength, f′c, of 3,000 psi (20.7 MPa).

Get Price

Concrete On Demand

Products We Offer Concrete 3000-5000 PSI, Custom Mix Designs Grout Mix, Flowable Fill, Stabilized Sand Hi- Early Strength Quick Set Lightweight Concrete

Get Price

Concrete Masonry Illinois Brick

Count on IBC for a wide-ranging selection of block in a variety of sizes, shapes, textures and colors for both commercial and residential use. From lightweight to normal weight, colored block to neutrals, smooth or split, we work to ensure you have the concrete block

Get Price
[]

ICC-ES Evaluation Report ESR-2202

3.3 Concrete Normal-weight and sand-lightweight concrete must comply with Sections 1903 and 1905 of the IBC or UBC, as applicable. 3.4 Steel Deck Panels Steel deck panels must comply with the configurations in Figure 6 and have a minimum base steel thickness of 0.034 inch (0.864 mm). Steel must comply with ASTM

Get Price

Pacific International Grout Co Low Density Cellular Concrete

Pacific International Grout Company is a heavy highway and tunnel specialty contractor and have placed record amounts of cellular foam concrete, including over 1,104,000 lineal feet of large diameter tunnel backfill and 741,026 lineal feet of small diameter pipe, in casing backfill.

Get Price
[]

TOLCO™ Fig. 109DD DDI+™† Concrete Deck Insert

Code compliant with the 2015 IBC, 2015 IRC, 2012 IBC, 2012 SAND-LIGHTWEIGHT CONCRETE OR NORMAL WEIGHT CONCRETE OVER STEEL DECK (MIN. 3,000 PSI) SAND-LIGHTWEIGHT CONCRETE OR (MIN. 3,000 PSI) See Design Information Topping (See Design Information) 3-7/8" (Typ) 3" Upper Flute

Get Price

Hacker Industries Gypsum Concrete Floor Underlayments

Designed for use in multi-family, commercial and institutional buildings with light-gauge steel framing and a corrugated steel deck, FIRM-FILL® CMD is a lightweight,

Get Price
[]

INTERNATIONAL BUILDING CODE STRUCTURAL S5

For a concrete deck slab on steel beam in which the slab is used to provide internal tie capacity, the floor system and roof system shall comply with the internal tie requirements of ACI 318, while the steel frame shall comply the other tie requirements (vertical, peripheral, and external column).

Get Price

Hilti Submittal Builder

Applicable for use in normal weight concrete, structural lightweight concrete, lightweight concrete over metal deck, and grout filled CMU. IBC 2015, COLA RR and Miami Dade County approvals. Kwik Bolt TZ Expansion Anchors Torque controlled expansion anchor which is especially suited to seismic and cracked concrete applications.

Get Price

How to Chose and Install Concrete Anchors to Satisfy the

Jul 01, 2009 · The 2006 International Building Code requires contractors and designers to make new choices in concrete anchors for cracked concrete.

Get Price
[]

ICC-ES Evaluation Report ESR-3371

3.3.1 Concrete Normalweight and sand-lightweight concrete must comply with IBC Chapter 19 or IRC Section R402.2, as applicable. The minimum concrete compressive strength at the time of PAF installation must be as noted in Table 2 or 3, as applicable.

Get Price

Residential Codes (IRC) Structural Building Components

Insulating Concrete Form Sill Plate Requirements. This Research Report will look specifically at the sill plate requirements according to the 2009, 2012, and 2015 International Residential Code (IRC) and International Building Code (IBC) and clarify if a sill plate is required in the following conditions Flat truss bottom chord bearing on ICF wall.

Get Price
[]

Light Weight Cantilever Sidewalk Using Prefabricated

Light Weight Decking weights are 4 to 12 psf Only 20% of reinforced concrete panels Prefabricated Bridge Elements Accelerated construction Incorporate features in shop fabrication Higher quality parts Lower installation cost Corrosion Resistance to chemicals and

Get Price
[]

TECHNICAL Coreslab Structures

Sand-Lightweight 2.7 3.3 3.8 4.6 5.4 Lightweight 2.5 3.1 3.6 4.4 5.1 *Standard "Coreslab" Plank Minimum Slab Thickness, Equivalent Thickness (in) for Fire Resistence Rating of Table 720.2.2.1 (IBC 2000) TECHNICAL Thickness of cover (in) for Fire Resistance Rating

Get Price
[]

TYPES OF CONSTRUCTION TYPE I TYPE II TYPE IV TYPE V

building elements listed in IBC Table 601 are of non-combustible materials, such as concrete and steel. The roof is also of non-combustible material, such as concrete or steel. TYPE II This type of building has steel or concrete walls, floors, and structural framework

Get Price

Lightweight Roof Pavers, Roof Deck Pavers

Lightweight Roof Pavers were invented to follow the natural slope of the roof and where an existing roof or new roof construction requires a lighter load. Cast with 1" of concrete laminated to a 1 1/2" of expanded polystyrene foam these pavers have the look and feel of a full weight paver yet weigh in at roughly half the load.

Get Price
[]

ICC-ES Evaluation Report ESR-3599

Concrete can then be cast over the insert. sa,insert 3.2 Concrete Normal-weight andlightweight concrete must sand conform to Sections 1903 and 1905 of the IBC. 3.3 Steel Deck Panels Steel deck panels must be in accordancewith the configuration in Figure 4 or Figure 4A and have a minimum base steel thickness of 20 gage [0.035 inch (0.899 mm)].

Get Price
User rating 1.7/5

Foam concrete Wikipedia

Foam concrete, also known as Lightweight Cellular Concrete (LCC), Low Density Cellular Concrete (LDCC), aircrete, foamed concrete, foamcrete, cellular lightweight concrete or reduced density concrete, is defined as a cement based slurry, with a minimum of 20% (per volume) foam entrained into the plastic mortar.

Get Price
[]

Fire Resistance of Concrete Structures

lightweight concrete can significantly improve the fire resistance of concrete walls as can be observed from the reduced thickness required for the same fire rating compared to concrete with normal weight aggregate. Concrete walls using lightweight aggregate maintain between 90- of their original compressive strength at tem-

Get Price
[]

Report ESR 3037

3.2 Concrete Normal-weight and lightweight concrete must conform to Sections . 1903 and 1905 of the IBC, as applicable. 3.3 Profile Steel Deck The profile steel deck must comply with the configuration in . Figures 4. and . 5 and have a minimum base-steel thickness of

Get Price
[]

CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP

A penthouse or other projec- tion above the roof in structures of other than Type I con- struction shall not exceed 28 feet (8534 mm) above the roof whereusedasanenclosurefortanksorforelevatorsthatrun to the roof and in all other cases shall not extend more than 18 feet (5486 mm) above the roof.

Get Price

Lightweight Construction NFPA Journal

Jul 01, 2009 · Lightweight construction uses "engineered lumber," a term generally used to describe a wood structural member that is fabricated through use of bonded fibers and materials and that is usually put together as a composite joist or beam.

Get Price

Buildex Lightweight Aggregate

Buildex is a construction material used primarily in the production of lightweight concrete masonry (Haydite block and Buildex SmartWall Systems concrete masonry units), lightweight structural concrete, asphalt chip seals and also as a lightweight geotechnical fill aggregate. There are many other significant uses, as well.

Get Price
[]

0ES Report ESR-2777 Toggler

3.3 Concrete ormal-weight or lightweight concrete must conform to Sections 1903 and 1905 of the IBC, as applicable. 3.4 Steel Deck Panels Steel deck panels must comply with the configuration in Figure 4 and have a minimum base-metal thickness of 0.035 inch (0.89 mm) [No. 20 gage]. Steel deck must

Get Price

Get a Free Quote

If you are interested in our company or products, welcome to visit our company or local offices; you can also get contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.